EQUIPMENTS

Name of Equipment / Instrument at CBEEV No of Units
Make/Vendor
Description
Application
Laboratory Grade Hot/Cold Temperature Chamber 3 Digiqual
  • Inner chamber Size : 500 x 415 x 750 mm
  • No of Trays : 3 Nos of Grilled Galvanised Trays
  • Inner chamber : SS 304
  • Outer Chamber : MS Powder Coated
  • Hardened Glass Provided to Front
  • Capacity : 6 Cu. Ft
  • Air Circulation : Fan Provided
  • Temp Range: 5 * C to 60 * C
  • Cooling System : Compressor Set up
  • Movement :Castor Wheels provided for Easy Movement
  • Side opening Fittings provided for wire entry
  • Temperature Controller
  • It is used to mount/keep Li-ion cells to test them at various temperatures
    19" (42U) Testing Rack 2 Bhuvanesh Sales (Schneider distributor) Rack 19" 42U/600W/800D It is used to mount multiple Cell Testers
    Resistance Welding Machine (Spot welding m/c) 1 S.S. Controls 3W/OL/15/resistance welding controller It is used to do the welding of Li-ion cells to make battery packs of different power capacity (Wh)
    Compressor 1 Whitestar Engg. Co.s 436 Serial No.: ES10 (Model No.) The air pressure from it is used to operate the pedal of the Weding Machine
    Electronic Load 2 CBEEV 2.5KW; 48V/60V It is used to discharge Li-ion batteries or is used for any Load Test
    Electronic Load 1 CBEEV 1.2KW; 48V/60V It is used to discharge Li-ion batteries or is used for any Load Test
    Soldering Station 2 VAR Tech It is used for soldering components on the printed circuit boards (pcb)
    Grid Tied Inverter 2 Consul 3KW Charger & Discharger It is used for charging and discharging Li-ion batteries
    Hot air oven (Heat Chamber) 1 In-lab Bottom Heated; Temperature Range 1800 C.Digital Temperature Controller with an Accuracy of ±1ºC.
    Heating Element are Provided at the Bottom only.
    Double Walled Inside Stainless Steel and Outside GI Steel Powder Coat Finish with Trays and Air Circulating Fan works on 220 volts A.C. Size : 12” x12” x12”
    It is used to test the Li-ion cells at various temperatures
    Bulk Charger 1 Exicom SMR 1.2KW ; 20 channels It is used to charge battery packs for 2W/3W (swappable) - 20 packs at the same time
    Oven for soldering components on PCBs (Printed Circuit Boards) 1 Croma 1200W, 240V, 50Hz. It is used to solder the components kept on the PCBs with soldering paste on them and then heated in oven
    Industrial Grade Hot/Cold Chamber 1 Digiqual
  • Appx 40 to 45 Kg Per Tray.
  • Inner chamber Size : 500 x 415 x 750 mm
  • Inner Chamber MOC : SS 304 1.5 mm Thck.
  • No of Trays : 3 Nos of Heavy Trays
  • Inner chamber : SS 304
  • Outer Chamber : MS Powder Coated
  • Hardened Glass Provided to Front.
  • Capacity : 6 Cu. Ft.
  • Air Circulation : Heavy Fan Provided.
  • Temp Range: 5 * C to 60 * C
  • Cooling System : Compressor Set up
  • Movement :Castor Wheels provided for Easy Movement
  • Side opening Fittings provided for wire entry
  • Temperature Controller
  • Touch Screen HMI Module Suitable for Above
  • Temperature Controller Profile With Ramp & Soak with Data Logging / USB Output.
  • HMI Size : 7 “
  • Profile Controller for Ramp /soak.
  • Data Report Transfer through USB in Excel Format
  • It is used to mount/keep e-bus battery packs to test them at various temperatures
    Grid Tied Inverter 1 Delta 125KW Charger & Discharger It is used for charging and discharging Li-ion batteries
    Power Supply 1 Sairus 0-150V, 0-5A It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Digital Rework Station 2 Soldron It is used to solder & de-solder components of PCBs
    Data Logger 1 Keysight
  • LXI Compliant Data Acquisition / Switch Unit with LAN & USB I/f & documentation in CD ROM &
  • 20 Channel Armature Multiplexer Module
  • It is used to log parameters like temperature, Voltage
    Cell Tester 5 Neware 5V, 6A It is used to test, analyse & characterise Li-ion cells and to test their life cycle
    Cell Tester 1 Neware 5V, 100A It is used to test, analyse & characterise Li-ion cells and to test their life cycle
    Impedance Tester 1 Hioki It is used to measure the impedance of the cell and is used for cell modeling
    Digital Multimeters 7 Ridhabh It is used for measuring various electrical parameters while testing
    Battery Swapper 1 Our custome design fabricated by Yadkai Our custome design fabricated by Yadkai It is used to take out the discharged batteries from electric vehicle and put charged batteries in the vehicle
    Charger Container with cooling system 1 It is used to keep the Charger for the Batteries
    Cast Iron Weights
  • 10 Nos. of 10 Kgs
  • 7 Nos. of 20 Kgs
  • It is used for weighing batteries, etc.
    ESD Safe Tables 5 Cir-q-tech They are used to safely do the testing of our R&D products
    Battery Testing System 5V, 10A 1 CBBEV-IITM
  • Max Voltage - 5V
  • Current per channel - 1A/3A/6A/10A
  • Paralleling Option - Any combination of channels can be paralleled
  • Max Paralleling Current - 40A
  • Current Resolution - 16 bit
  • Voltage Resolution - 16 bit
  • Current Accuracy - 0.05%
  • Voltage Accuracy - 0.05%
  • Rise time - 50 msec
  • Used in cell testing for small cyclindrical cells upto 10 Amps and Prismatic and pouch cells for upto 40 Amps at different DOD, C-rates and Temperatures.
    Power Supply 2 Aplab; 0-64V, 10A It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Cathode Ray Oscilloscope 1 Keysight 50MHz It is used used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others.
    Power Supply 4 Aplab 0-32V, 2A It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Function Generator 1 Scientific 3MHz It is used to generate different types of electrical waveforms over a wide range of frequencies.
    1 Ph. Variac 1 AE 4A Variac is basically variable autotransformer. It is used as regular transformers but handle lower voltages
    3 Ph. Variac 1 AE 15A Variac is basically variable autotransformer. It is used as regular transformers but handle lower voltagesVariac is basically variable autotransformer. It is used as regular transformers but handle lower voltages
    Isolation Transformer3 Ph. Variac 1 Maxind 230V; 250VA It is used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons.
    Power Supply 1 Aplab 64V, 5A It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Cathode Ray Oscilloscope 1 Agilent 70 MHZ It is used used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency,rise time, time interval, distortion and others
    Soldering Station 3 weller It is used for soldering components on the printed circuit boards (pcb)
    Digital Multimeter 3 Rishabh It is used for measuring various electrical parameters
    Current Clamp Meter 1 Hioki 0-1000A It is used measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents.
    Power Meter 2 Yokogawa It is used to measure input/output power
    Power Supply 1 Lambda 80V, 42A It converts unregulated AC into a constant DC.Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Variac 1 Bharat single phase , 4A Variac is basically variable autotransformer.It is used as regular transformers but handle lower voltages
    CRO 1 Keysight It is used used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others.
    Rheostat 5 Asian 5 Ohms, 20A It is a variable resistor. It is used to control the electrical resistance of a circuit without interrupting the flow of current
    Rheostat 1 Asian 1200 Ohms. 2 A It is a variable resistor. It is used to control the electrical resistance of a circuit without interrupting the flow of current
    LCR Meter 1 Agilent An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component
    Rheostat 1 Asian 100 Ohms, 3.5A It is a variable resistor.It is used to control the electrical resistance of a circuit without interrupting the flow of current
    Power Supply 1 Aplab 64V, 20A It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Power Supply 60V/15A-17A(2 nos) 1 Chinese
    Racks for swapping station-2Nos
    19" Rack with accessories and extra accessories 1 Bhuvanesh With smps Used to mount cell testers, etc. and route the cables
    Tachometer (Digital) 1 Kusam Meco KM-2234BL Used to measure speed in rpm of rotating shaft as in motors, etc
    DC Power Supply (64V, 20A) 1 Aplab Linear Power Supply; HO11L64200518006 It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Oscilloscope 4 channel 200MHz 1 Keysight MSOX3024T; MY58262424 It is used used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others
    Digital Vernier Calipers 150mm 1 Mitutoyo 150mm; 90173010 It measures internal dimensions, outside dimensions, and depth. It can measure to an accuracy of one thousandth of an inch and one hundredth of a millimeter
    Power Supply 64V, 10A 1 Aplab LD6410; 64V, 10A (Dual); HO11D64100718013 It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Power Supply 64V, 20A 1 Aplab L6420; 64V, 20A; HO11L64200718012 It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Power Supply 64V, 20A 1 Aplab L6420; 64V, 20A; HO11L64200718012 It converts unregulated AC into a constant DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits
    Oscilloscope 100MHz, 2 channel 1 Keysight DSOX1102G; CN57266152 It is used used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others
    LCR Meter 1 Keysight U1732C; MY58290022 It is used to measure the inductance, capacitance, and resistance of an electronic component
    LCR Meter 1 Keysight U1732C; MY58290022 It is used to measure the inductance, capacitance, and resistance of an electronic component
    Data Logger with 20 channels 1 Keysight 34972A; MY57011380 It is used to log parameters like temperature, Voltage, etc
    H.V.Differential Probe 100MHz, 6500V 1 Pintek D P100 100MHz, 6500V; 9030; 20182010 It is used for measuring the voltage difference between two test points where neither test point is at ground. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability
    H.V.Differential Probe 100MHz, 6500V 1 Pintek D P100 100MHz, 6500V; 9030; 20182011 It is used for measuring the voltage difference between two test points where neither test point is at ground. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability